Specification
Transducer
Description
Range on liquids SUMPI and SUMPI FM
Range on Solids SUMPI
Range on Liquids SMPI MR and SUMPI LR
Range on solids SUMPI MR and SUMPI LR
Minimum Blanking
Frq. kHz
Beam Angle
KAB 10
General purpose
10 m
5 m
15 m
5 m
0.3 m
44
11°
KAB 10 C
Above with temp. compensation
10 m
5 m
15 m (LR only)
5 m (LR only)
0.3 m
44
11°
KAB 10 T
PTEE Lined transducer with flange
10 m
5 m
15 m
5 m
0.3 m
44
11°
KAB 10 F
Solid applications
N / A
10 m
15 m
15 m
0.3 m
44
11°
KAB 20
Medium range
N / A
N / A
30 m
30 m
1 m
15.4
KAB 20 H
Medium range with dust
N / A
N / A
30 m
30 m
1 m
15.4
KAB 60
Long range
N / A
N / A
60 m (LR only)
60 m (LR only)
1.5 m
12.5

Transducer Description
Facing material
Body Material
IP Protection
Approvals
Temperature range
Mounting
KAB 10 General purpose
Polyurethane
PVC
IP 68
Exm llT6
-20°C to + 80°C
1 inch BSP
KAB 10 C Above with temp. compensation
Polyurethane
PVC
IP 68
Exm llT6
-20°C to + 80°C
1 inch BSP
KAB 10 T PTEE Lined transducer with flange
PTEE ( TEFLON )
PVC
IP 68
Exm llT6
-20°C to + 80°C
3,4 or 6 inch flange
KAB 10 F Solid applications
Polyurethane Foam
PVC
IP 62
Exm llT6
-20°C to + 80°C
1 inch BSP
KAB 20 Medium range
Polyurethane Foam
PVC
IP 62
Exm llT6
-20°C to + 80°C
1 inch BSP
KAB 20 H Medium range with dust
Polyurethane Foam
PVC
IP 62
Exm llT6
-20°C to + 80°C
1 inch BSP
KAB 60 Long range
Polyurethane Foam
PVC
IP 62
Exm llT6
-20°C to + 80°C
1 inch BSP
Aiming Kit
It is advisable to purchase an Aiming Kit when a Transducer is to be used on any solid application. This helps to position the Transducer correctly to maximise the return echo.

KAB's range of transducers are available with or without Temperature Compensation.